DATOS DEL CLIENTE |
NOMBRE
|
Hugo Santos Leon
|
UBICACION
|
Chillan
|
FECHA INICIO
|
2021-11-23
|
FECHA TERMINO
|
0000-00-00
|
DATOS DEL POZO |
DIAMETRO | 10 |
PROFUNDIDAD | 90 |
VOLUMEN ESTIMADO | |
NIVEL ESTÁTICO | 3.60 |
ESTRATIGRAFÍA DE LA PERFORACIÓN | 0 a 3 tierra relleno 3 a 8 arena fina y arcilla 8 a 16 arena gruesa 16 a 23 arena gruesa y arcilla 23 a 35 arena gruesa 35 a 36 arena gruesa y ripio fino 36 a 62 arena gruesa 62 a 64 arena gruesa y greda 64 a8 4 arena gruesa 84 a 90 arena gruesa y trazos de gravilla |
TRAMOS RANURADOS | 0 a 36 ciego 36 a 42 ranurado 42 a 48 ciego 48 a 81 ranurado 81 a 84 ciego de 84 a 87 ranurado 87 a 90 ciego corona |
DATOS DEL SISTEMA HIDRÁULICO |
BOMBA | STAIRS |
MODELO BOMBA | SP1100-3A |
HP MOTOR | 75 |
VOLTAJE | 380 |
DATOS GEOFÍSICOS |
ESTE | 751393 |
NORTE | 5941895 |
ZONA | 18 |
COORDENADAS | -36.635238563906,-72.188302770213 |
INTEGRANTES | |
GPS |  |
Mapa
|
|
Gasto Variable (Estabilizaciones)
N° | Caudal (lts/s) | Nivel (m) | Depresión (m) | Caudal (lt/s/m) | 0 | - | 3.60 | - | - | 1 | 24 | 7.59 | 3.99 | 6.015 | 2 | 37 | 13.04 | 9.44 | 3.919 | 3 | 53 | 22.60 | 19 | 2.789 | 4 | 65 | 30.74 | 27.14 | 2.395 | 5 | 0 | 7.59 | 3.99 | 0 |
|
Gasto Constante
Se Bombeó un Caudal | 60 lt/s | Se estabilizo a | 26.29 m | Depresión | 22.69 m | Qe | 2.644 lt/s/m |
|
Tiempo (min) | Nivel (m) | 0 | 3.60 | 1 | 6.15 | 2 | 6.24 | 3 | 6.35 | 4 | 6.43 | 5 | 6.50 | 7 | 6.60 | 9 | 6.68 | 11 | 6.78 | 13 | 6.83 | 15 | 6.87 | 20 | 7.00 | 25 | 7.09 | 30 | 7.27 | 40 | 7.35 | 50 | 7.51 | 60 | 7.56 | 75 | 7.59 | 90 | 7.59 |
|
Gastos Variable 1
Caudal de Prueba 24 lts/s
|
|
Tiempo (min) | Nivel (m) | 0 | 7.59 | 1 | 9.85 | 2 | 10.06 | 3 | 10.19 | 4 | 10.30 | 5 | 10.38 | 7 | 10.57 | 9 | 10.65 | 11 | 10.84 | 13 | 10.91 | 15 | 10.97 | 20 | 11.25 | 25 | 11.44 | 30 | 11.67 | 40 | 12.16 | 50 | 12.60 | 60 | 12.89 | 75 | 12.99 | 90 | 13.04 | 105 | 13.04 | 120 | 13.04 |
|
Gastos Variable 2
Caudal de Prueba 37 lts/s
|
|
Tiempo (min) | Nivel (m) | 0 | 13.04 | 1 | 15.50 | 2 | 15.73 | 3 | 15.93 | 4 | 16.18 | 5 | 16.31 | 7 | 16.68 | 9 | 16.78 | 11 | 17.03 | 13 | 17.29 | 15 | 17.52 | 20 | 18.00 | 25 | 18.36 | 30 | 18.80 | 40 | 19.13 | 50 | 19.78 | 60 | 20.41 | 75 | 20.85 | 90 | 21.32 | 105 | 21.82 | 120 | 22.20 | 150 | 22.57 | 180 | 22.60 | 210 | 22.61 | 240 | 22.60 |
|
Gastos Variable 3
Caudal de Prueba 53 lts/s
|
|
Tiempo (min) | Nivel (m) | 0 | 22.61 | 1 | 26.96 | 2 | 28.64 | 3 | 28.89 | 4 | 29.10 | 5 | 29.14 | 7 | 29.48 | 9 | 29.73 | 11 | 29.85 | 13 | 29.95 | 15 | 30.01 | 20 | 30.53 | 25 | 30.55 | 30 | 30.55 | 40 | 30.74 | 50 | 30.70 | 60 | 30.74 | 75 | 30.74 | 90 | 30.74 | 105 | 30.74 | 120 | 30.74 | 150 | 30.74 | |
Gastos Variable 4
Caudal de Prueba 65 lts/s
|
|
|
|
Tiempo (min) | Nivel (m) | 0 | 3.88 | 1 | 18.77 | 2 | 23.59 | 3 | 24.00 | 4 | 24.32 | 5 | 24.60 | 7 | 24.98 | 9 | 25.15 | 11 | 25.32 | 13 | 25.65 | 15 | 25.79 | 20 | 25.93 | 25 | 26.04 | 30 | 26.10 | 40 | 26.13 | 50 | 26.15 | 60 | 26.17 | 75 | 26.20 | 90 | 26.21 | 105 | 26.21 | 120 | 26.22 | 150 | 26.24 | 180 | 26.25 | 210 | 26.25 | 240 | 26.25 | 300 | 26.25 | 360 | 26.27 | 420 | 26.27 | 480 | 26.27 | 540 | 26.27 | 600 | 26.28 | 660 | 26.28 | 720 | 26.28 | 780 | 26.28 | 840 | 26.28 | 900 | 26.28 | 960 | 26.29 | 1020 | 26.29 | 1080 | 26.28 | 1140 | 26.28 | 1200 | 26.28 | 1260 | 26.29 | 1320 | 26.29 | 1380 | 26.29 | 1440 | 26.29 | |
Gastos Constante
Nivel Estático 3.60 m
Caudal de Prueba 60 lts/s
|
|
Tiempo (min) | Nivel (m) | 0 | 30.74 | 1 | 13.28 | 2 | 12.17 | 3 | 11.55 | 4 | 11.21 | 5 | 10.81 | 7 | 10.32 | 9 | 9.86 | 11 | 9.54 | 13 | 9.28 | 15 | 8.91 | 20 | 9.37 | 25 | 8.19 | 30 | 7.84 | 40 | 7.59 |
|
Recuperación Gastos Variable
Nivel Estático 7.59 m
|
|
Tiempo (min) | Nivel (m) | 0 | 26.29 | 1 | 14.37 | 2 | 12.90 | 3 | 11.76 | 4 | 10.84 | 5 | 9.91 | 7 | 8.69 | 9 | 8.03 | 11 | 7.51 | 13 | 7.13 | 15 | 6.95 | 20 | 6.72 | 25 | 6.47 | 30 | 6.29 | 40 | 6.03 | 50 | 5.86 | 60 | 5.63 | 75 | 5.40 | 90 | 5.24 | 105 | 5.13 | |
Recuperación Gastos Constante
Nivel Estático 5.13 m
|
|
Caudal (lts/s) | Nivel (m) | 0 | 3.60 | 24 | 7.59 | 37 | 13.04 | 53 | 22.60 | 65 | 30.74 |
|
Curva Agotamiento
Nivel Estático 3.60 m
|